Syp 3t MRI Superconducting MRI System

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Ultrasound Scanner
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2006-11-21
Registered Capital
739010.91 USD
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, IATF16949
  • Syp 3t MRI Superconducting MRI System
  • Syp 3t MRI Superconducting MRI System
  • Syp 3t MRI Superconducting MRI System
  • Syp 3t MRI Superconducting MRI System
  • Syp 3t MRI Superconducting MRI System
  • Syp 3t MRI Superconducting MRI System
Find Similar Products

Basic Info.

Model NO.
3.0T MRI
Group
Middle-aged and Old
Transport Package
Wooden Box
Specification
799 PET+CT
Trademark
SYP
Origin
China
HS Code
90221990
Production Capacity
200 Set

Product Description

SYP Hospital 3T  MRI Superconducting MRI system
Syp 3t MRI Superconducting MRI System

Syp 3t MRI Superconducting MRI System

SYP 3.0T superconducting MRI manufacturers, completely broke the high-end MRI monopoly by foreign brands.SYP is a new generation of superconducting MRI product has the advantages in novel design, excellent performance, high comfort and more patient care technology. The system adopts the international advanced hardware platform together with ergonomic operating software design, its advanced scan sequences and imaging technology, produces the customer with high stability and excellent performance, high signal-to-noise ratio, high resolution, high contrast clinical imaging and faster scanning speed.
1), it config 4k cold head from Japan, the brand is Sumitomo, that provides "zero" consumption of the liquid helium
), its cold head sound reduction technology helps to reduce the patient's claustrophobic fear, effectively avoid the involuntary movement which may cause the image artifacts and other potential risk.

3), it has fastest scanning speed, and the image quality is also much better than 1.5T MRI.
4), it using all famous parts suppliers ensuring the stable system quality.
Gradient sub system

Gradient sub system directly determines the spatial encoding of MRI system, it produces the signal information, at the same time it can perform GR series sequence scanning, it is the foundation of MRI system's spatial resolution ability, gradient sub system also directly affect the scanning image thin slice scanning.

No. Item Specification
One Equipment Introduction  
1 Use For all parts of the body MRI Scan
Two Magnet System  
1 magnetic field Strength 3.0T
2 Center frequency 127.7MHz
3 Magnet Type Superconducting Magnet
4 Magnet Material Niobium-titanium alloys
5 Anti-electromagnetic interference Yes
6 Magnet stability 0.1 ppm/h
7 Uniformity of magnetic field Typical values, V-RMS measurements
7.1 10cm DSV 0.005ppm
7.2 20cm DSV 0.027ppm
7.3 30cm DSV 0.056ppm
7.4 40cm DSV 0.250ppm
7.5 45cm DSV 0.460ppm
7.6 50cm DSV 1.500ppm
8 Compensation technology of magnetic field shimming Yes
9 Shim mode Active uniform field + passive leveling
10 Magnet weight (with liquid helium) 4600kg
11 Magnet length (excluding shell) 160cm
12 Patient aperture. 60cm
13 Cooling mode Liquid helium
14 Liquid helium consumption rate 0
15 Volume of liquid helium 1450L
16 Cold head Type 4K Cold Head
17 5 Gauss line range 3.1m x 3.1m x 5.5m
Three Gradient System  
1 Gradient Control Technology Full digital real Time
2 Gradient Cooling Mode Water
3 Maximum gradient intensity 46mT/m
4 Maxi gradient slew rate 288T/m/s
5 Minimum gradient rise time 0.159ms
6 Maximum gradient field, maximum gradient switching rate and maximum FOV can be achieved simultaneously Yes
7 Max duty ratio 100%
8 Shielding mode Active shielding
9 Gradient working mode Non-resonant type
10 Gradient Noise Reduction Technology Yes
Four RF System  
1 Number of independent RF sources 1 or 2
2 Number of independent RF amplifiers 1 or 2
3 Each RF source can independently adjust the RF pulse phase, waveform, amplitude Yes
4 RF Transmitter Power 35kW or 18kW * 2
5 Max RF transmit field 20μT
6 RF Power Amplifier Type Water-cooled / Digital Interface
7 Transmitter Coil auto tuning Yes
8 Number of independent RF channels 16 / 32
9 RF Receiver Sampling rate 100MHz
10 Receive dynamic range (1Hz bandwidth) 140db
11 Noise coefficient 0.5dB
12 Full digital demodulation and filtering technology Yes
13 RF Energy Monitoring  
13.1 Real-time digital RF energy Monitoring Yes
13.2 Real-time digital RF energy accumulation monitoring Yes
13.3 Real-time digital RF energy accumulation monitoring Yes
14 RF receiver coils and related technologies  
14.1 Orthogonal transmitting / receiving Yes
14.2 Head-neck coils 24 Channel
14.3 Body Coil 12 Channel
14.4 Spine Coil 18 Channel
14.5 Large Flexible Multi-function coil 8 Channel
14.6 Breast Dedicated coil 8 Channel
14.7 Knee Dedicated coil 8 Channel
14.8 Shoulder Dedicated coil Optional
14.9 Ankle Dedicated coil Optional
14.10 AIT Scanning technology Yes
14.11 Note: coil configuration is subject to the final contract
Five Computer  
1 CPU 3.4GHz
2 Number of processor digits 64bit
3 Memory capacity 8GB
4 Hard disk capacity 500GB
5 Image storage capacity (512 matrix) 0.6million
6 Display resolution 1920 x 1200
7 Display size and specifications 24 inch
8 Maximum acquisition matrix 1024 x 1024
9 Maximum Reconstruction matrix 1024 x 1024
Six Post-processing interface  
1 Software Control camera Technology Yes
2 DICOM 3.0 interfaces and PACS network connections (including print, transmit, receive, query , worklist, MPPs ) Yes
3 Standard Laser Camera Digital interface Yes
Seven Scan parameters  
1 X axis Max FOV 500mm
2 Y axis Max FOV 500mm
3 Z axis Max FOV 500mm
4 Minimum FOV 5mm
5 Thinnest layer thickness 0.1mm
6 2D SE Shortest sequence TR time (128 matrix) 7ms
7 2D SE Shortest sequence TE time (128 matrix) 2.4ms
8 2D FSE Shortest sequence TR time (128 matrix) 7ms
9 2D FSE Shortest sequence TE time (128 matrix) 2.4ms
10 2D FSE Sequence minimum echo spacing (128 matrix) 2.4ms
11 2D FSE sequence maximum echo chain length (ETL) 512
12 2D GRE Shortest sequence TR time (128 matrix) 1.0ms
13 2D GRE Shortest sequence TE time (128 matrix) 0.6ms
14 3D GRE Shortest sequence TR time (128 matrix) 1.2ms
15 3D GRE Shortest sequence TE time (128 matrix) 0.5ms
16 EPI Sequence minimum echo interval (128 matrix) 0.57ms
17 EPI Shortest sequence TR time (128 matrix) 4.7ms
18 EPI Shortest sequence TE time (128 matrix) 1.3ms
19 Maximum dispersion weighted b value 10000
Eight Scanning technology and sequence  
1 Spin echo sequence (FSE) Yes
1.1 2d/3d Fast spin echo Yes
1.2 SE sequences measured by tissue relaxation time Yes
1.3 SE sequences with selectable angles Yes
1.4 Single echo, dual echo and multi-echo technology Yes
1.5 Single excitation fast spin echo sequence Yes
1.6 Fat-sat sequence Yes
1.7 Fast Fat saturation Technology Yes
1.8 Water-sat sequence Yes
1.9 Reverse recovery (IR) Yes
1.10 General IR sequence Yes
1.11 FLAIR Yes
1.12 Fast T1-FLAIR Yes
1.13 Fast T2-FLAIR Yes
1.14 Rapid inversion recovery sequence (fat-sat, water-sat) Yes
1.15 Short TI inverse echo water-fat separation imaging Yes
1.16 "True" inversion recovery sequence (contrast imaging of gray-white matter) Yes
2 Gradient echo (2d/3d), including Yes
2.1 Multi-layer gradient echo Yes
2.2 2d/3d residual magnetization removal gradient echo technology Yes
2.3 2d/3d residual magnetization gradient echo technology Yes
2.4 Heavy T2 weighted High Contrast sequence Yes
2.5 3D Gradient Echo Technology Yes
2.6 Fast steady-state progressive gradient Echo Yes
2.7 Super-fast field echo sequence Yes
2.8 Three-dimensional imaging technology Yes
3 Planar echo imaging (EPI) Yes
3.1 Single-excitation planar echo imaging technology Yes
3.2 Multi-excitation planar echo imaging Yes
3.3 Spin echo EPI Yes
3.4 Gradient echo EPI Yes
3.5 Reverse EPI Yes
3.6 High resolution EPI Collection Yes
4 Neuroimaging technology Yes
4.1 High resolution anatomical imaging Yes
4.2 High resolution three-dimensional imaging technology of inner ear Yes
4.3 Full Spinal cord imaging Yes
5 Diffusion imaging technology Yes
5.1 ADC Imaging Yes
5.2 Isotropic acquisition Yes
5.3 Anisotropic acquisition Yes
5.4 ADC Value Measurement Yes
5.5 ADC-map Yes
5.6 Automatic acquisition and processing Yes
5.7 Single-shot EPI Yes
5.8 Multi-shots EPI Yes
5.9 Real-time diffusion imaging Yes
5.10 Automatically generate ADC diagram Yes
5.11 Optional optimization B value Yes
6 Vascular imaging technology Yes
6.1 Time Of Fly Technology (2d/3d) Yes
6.2 Imaging technology of arteriovenous separation Yes
6.3 MTC technology Yes
6.4 Maximum density projection technology Yes
6.5 Variable reversal Angle RF technology Yes
6.6 MIP Yes
6.7 2d/3d Water Imaging Technology (MRCP, MRU) Yes
6.8 Real-time interactive MIP Yes
7 Artifact removal technology Yes
7.1 Fluid compensation Yes
7.2 Respiratory compensation Yes
7.3 Flow correction Yes
7.4 Regional saturation Technology Yes
7.5 Deconvolution Artifact Removal technology Yes
7.6 Motion Artifact Elimination technology Yes
7.7 Image filtering Enhancement technology Yes
7.8 K Space Noise Reduction technology Yes
7.9 Ring artifact suppression Yes
8 Section-scan technology Yes
8.1 Semi-scanning technology Yes
8.2 Full directional partial coding acquisition technology Yes
8.3 Rectangular FOV acquisition technology Yes
8.4 Three-dimensional overlapping continuous acquisition technology Yes
8.5 Parallel acquisition and reconstruction technology Yes
8.6 Partial echo Acquisition Yes
9 Other imaging technology Yes
9.1 Short TR TE Fast Imaging Yes
9.2 Three-dimensional positioning system Yes
9.3 Positioning technology of radial slice layer Yes
9.4 Scan pause Yes
9.5 Variable Bandwidth technology Yes
9.6 Pre-scanning technology Yes
9.7 Signal noise ratio display function Yes
9.8 Mute Scanning technology Yes
9.9 Real-time interactive imaging Yes
9.10 Real-time localization Yes
9.11 Real-Time Interactive parameter change Yes
9.12 High Resolution imaging Yes
9.13 Combined scan function Yes
9.14 Water Saturation Technology Yes
9.15 Pre-saturated technology Yes
9.16 Maximum saturation zone number 3
9.17 Parallel saturation Zone Yes
9.18 Adjoin saturation Zone Yes
9.19 Fat saturation Technology Yes
9.20 Signal averaging technology Yes
9.21 Frequency Coding Direction Extended acquisition Yes
9.22 Phase coding direction expands acquisition Yes
9.23 Partial Center scanning technology Yes
9.24 Variable K space Filling method Yes
9.25 K Fast Space Acquisition Yes
9.26 Coil Sensitivity correction technology Yes
9.27 Enhancement technology Yes
9.28 Correction technology of image luminance uniformity Yes
9.29 Automatic Center Scanning technology Yes
9.30 Image reconstruction Technology Yes
9.31 Image interpolation Amplification Technology Yes
9.32 Image Distortion Correction Technology Yes
10 Advanced clinical application packages Yes
10.1 Neuro Imaging software Package Yes
10.2 Body Imaging software Package Yes
10.3 Bone and joint imaging software Package Yes
10.4 Tumor Imaging software Package Yes
10.5 Breast Imaging software Package Yes
Nine The patient examine environment  
1 Two-way patient call system Yes
2 Magnetic noise-reducing headphones Yes
3 Aperture Ventilation system Yes
4 Aperture lighting system Yes
5 Embedded display Yes
5.1 Patient monitoring System Yes
5.2 Bedside Patient Control system Yes
6 Patient Emergency call Device Yes
7 Maximum load bearing of inspection bed 200KG
8 Minimum bed height for inspection beds 62cm
9 Maximum speed of horizontal motion of scan bed 20cm/s
10 Scan bed Length 245cm
11 Maximum scanning range >150cm
12 Multi-station stitching Yes
13 Bedside Emergency brake button Yes
14 Bedside Switch Yes
15 Breath gating Yes

 


Syp 3t MRI Superconducting MRI System
Syp 3t MRI Superconducting MRI System
Our Services
1.For all your inquires about us, we will reply you in  detail within  24 hours.
2.We own professional team with professional attitude to recommend products and services  for you.
3.The  products  have one year free warranty,  after which they  can still be provided after-sales service.
4. We offer OEM services. And we can print your own logo on the product.
5. We have well-experienced engineers, who can help you better use our products.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier